The door system of microwave ovens, including hinges, microwave seals and other associated parts, shall be constructed as to withstand wear that may be expected in normal use. Therefore compliance is checked by subjecting the door system to a total of 100000 cycles of operation.

The door system is subjected to 10000 cycles while the appliance is supplied at the rated input and containing an appropriate microwave absorbing load, and to 10000 cycles of operation with the power switched off. The device for opening the door is attached to the door handle or applied to the normal operating area (as shown in the figure).